Page view 9
18
GR 2
6 Mic/Line Inputs with EQ
Balanced inputs are provided on terminal blocks
for convenient pre-wiring, with Mic 1 duplicated
on XLR for quick plug-and-play. Each input has
selectable +15V phantom power, protected mic/line
pads and gain trimmers. There is a mic priority
function for chairman or MC override, and a mic
mute. The mic also has dedicated EQ with swept
HPF, swept MF and shelving HF. An expander
input allows more mics to be added to the mix.
3 (or 4) Stereo Music Inputs
Music channels are provided on RCA inputs with
protected -10/+4 level settings. Mic/line 5/6 can
be configured as a stereo input providing a 4 mic,
4 stereo line system. Inputs may be configured
one at a time, or all together
FEATURES
:
Paging & Music Priority Override
GR2 offers a dedicated paging channel with
tailored EQ for speech intelligibility. The source
can be configured from Mic 1 and/or an external
input or alarm message and the zone program is
ducked when a page signal is detected. Music 1
may be configured as a priority input for jukebox
and pre-recorded message override.
Mono & Stereo Zone Outputs
Outputs are available on both RCA and terminal
blocks for pre-wiring or plug-and-play operation.
Stereo Zone 1 may be configured for music only
or music + mics, and mono Zone 2 can be
configured for mics, music or music + mics.
VCAs are provided for ducking, alarm override and
remote level control. Zone 1 features a 2-band EQ
and a mono switch.
Mono Aux Output
A versatile output for additional zone, mic expander,
paging distribution, sub bass and more is provided
on RCA and terminal block connectors. It is
configurable as page out, mic mix, follow Zone 1
or Zone 2, and has a switchable 100Hz LPF for
sub-bass feed.
Remote Control
The GR2 uses standard RJ45 CAT5 cable for
installation. ‘Zone remote’ allows remote level and
source selection for both zones over a single cable.
A 10V DC control input is provided for custom wired
switches or potentiometer, third party interface or
the ALLEN&HEATH PL-12 wall plate. The PL-5
hand-held IR controller is available for use with the
PL-12. ‘Utility remote’ allows remote mic priority
and mute switching, page selection and alarm override.
Configuration Protection
All settings are configured from the front panel.
Preset dip switches are letter coded, and trimmers
recessed for screwdriver access. A cover plate
protects the settings and provides space for fitting
a custom label. Any of the rotary knobs may be
removed and hole plugs fitted as required.
:
?
Technical Specifications
0dBu = 0.775 Volts rms, +4dBu = 1.23V rms, 0dBV = 1 Volt rms, -10dBV = 316mV rms:
MIC/LINE input
Balanced XLR (1), terminals Pad out = >2k ohm,
-60 to -20dBu
Pad in = >10k ohm,
-30 to +10dBu
Phantom power +15V DC
STEREO input
Dual RCA phono >10k ohm,
-10dBV or +4dBu
ZONE output
RCA, Z balanced terminals <75 ohm, 0dBu,
+20dBu max
EXPANDER input
Balanced terminals >10k ohm, 0dBu
PAGE input
Balanced terminals >10k ohm, 0dBu
Mic EQ
HPF 20-400Hz,
MF peak/dip +/-12dB @ 200Hz to 5kHz,
HF +/-12dB 10kHz shelf
Zone 1 EQ
LF +/-12dB 80Hz shelf,
HF +/-14dB 10kHz shelf
PL-12 Wall Plate
Part of the ALLEN&HEATH PL Series, this
intelligent wall plate provides remote level and
source selection for the GR2. Two may be
connected using a
single CAT5 cable,
one configured to
Zone 1, the other to
Zone 2. Additional
custom wiring
options are provided
for Zone 2 follow
Zone 1 room combiner
switching and a wall
plate disable function.
PL-5 IR Controller
This hand-held controller
works with the PL-12
IR sensor to
duplicate the
wall plate
controls and add
further functions
including source
mute and presets for
favourite level and source
selection settings.
The GR2 is a new 1U rack or desk mount 9-input, 4-output, analogue zone mixer for demanding but budget-
conscious installations requiring sound for live entertainment, paging, background music, conferences,
presentations and a diverse range of modern architectural applications. The GR2 offers the installer a host of
front panel preset switches and trimmers to meet each special requirement. After installation, the settings are
protected by a cover plate and unused controls may be blanked off to keep things simple for non-technical
operators. There is a combination of XLR/RCA and screw terminal connectors for pre-wired or plug-and-play
installation and extensive remote control capability using standard Cat5 cable.
Page EQ
HPF 150Hz, LPF 8kHz
Remote control
Level 0V = off +10V DC = max
Source select 1=2V, 2=4V, 3=6V, 4=8V
Ducking
Signal detect threshold -20dB
Music priority
Signal detect threshold -20dB
Release short = 2 sec,
long = 12 sec
Signal meters
2-colour LED signal = -14dBu,
peak = +14dBu
Power supply
100 to 230V 47-63Hz AC, universal mains input
25VA max
Mechanical specifications - Dimensions in mm
1U rack or desk mount (removable rack ears)
Width Height Depth
Desktop 482mm 44/49mm 235mm
(19”) (1.75”) (9.3”)
Weight 3.6kg (8 lb)
PL Remote Controllers
Page view 9
1 2 3 4 5 6 7 8 9 10

Comments to this Manuals