The GR05 is an affordable yet high quality ‘plug and play’ analogue 1U rack solution for sound installations,
mixing up to 2 mic and 3 stereo sources for up to 4 output zones. It presents a very simple interface for the
operator, but has amazing installer configurable flexibility protected ‘under the hood’. It provides tools such
as level matching, metering, routing matrix , EQ, ducking, VCA remote control and expandability to satisfy the
many demands of each installation.
The GR05 is at home in small but high quality professional sound installations providing zoned background music and announcements,
with sources such as microphones, CD, 2-track players, retail radio feeds, video sound, jukeboxes, etc. Venues where GR05 can be
found include bars, shops, sports centres, restaurants, public galleries and venue foyers.
GR 05
2 Microphone Inputs
The GR05 is furnished with 2 balanced mic inputs
on XLR, both of which have rear panel gain controls.
Removal of the top panel allows access to internal
jumper links, providing a 30dB attenuator pad, +15V
phantom power and a high pass filter at 200Hz.
Internal trimmers also provide 2-band EQ, hi-mid
frequency with sweep and LF shelving. The front
panel has 3-colour LED meters, and level controls
for all routed outputs.
Stereo Inputs
3 RCA sockets are provided for stereo inputs, and
internal jumper links allow access to -10dBV to
+4dBu level matching. 3-colour LED meters and
level controls are also provided for the stereo inputs
on the front panel.
FEATURES
:
Outputs XLR
4 XLR connectors are provided for the outputs,
which are internally configured by the jumper links
for -10dBV to +4dBu. The outputs can be grouped
and front panel level controls can be disabled using
the internal. Internal trimmers also provide shelving
EQ for HF and LF.
Other configurable functions include VCA control
and outputs which can be assigned to front panel
controls or alternatively, remote control operation.
Zone muting is possible via a front panel switch
and LED indicator.
Routing Matrix
All inputs can be routed to any combination of
outputs direct, or via VCA control, so that the direct
path is not affected by output level controls and
ducking. Matrix assigment is achieved using
internal jumper links.
Remote Control
VCA path remote control can be configured by the
installer on internal jumpers. The expander option
(using another GR05 acting as slave to the main
unit and connected by a 25-pin D connector)
includes a remote DC input for each of the 4 outputs.
Maximum output level
Impedance balanced +20dBu into 2k ohm
Frequency response
20Hz to 30kHz 0/-1dB
Distortion - measured at +12dBu 1kHz Line in to Output
< 0.005%
Crosstalk measured at 1kHz
Channel shutoff < -90dB
Interchannel < -80dB
Channel pan < -75dB
Noise 22Hz - 22kHz referred to 150 ohm source
Mic EIN -128dB
Line preamp at 0dB gain -91dBu
Mix noise (all routed) < -86dB
Inputs + Output Meters
3 colour LED
Red: Peak: on 5dB before clipping
Yellow: 0dB
Signal: dynamic indication from -12dB
Internal headroom
+20dB
Routing
Assignable 9 in, 4 (x2) Out
Crosspoint Matrix
Output Levels Control
High performance VCA system
Routed Direct
Internal trimmer
-10dBV to +4dBu
Routed via VCA Front panel level control or
External remote level control
Switch operated zone mute
option link
Ducking options Internal Trimmer
-10dBu to +4dBu
Ducking - Release fast or slow links
Depth -10dB, -20dB or Mute links
Internal & External Ducking circuits.
Internal Trigger from mic 1
and mic 2 by option links.
External Trigger from opto
isolated input
EQ
Mic Inputs HF/MF Swept
Peak/Dip, LF Shelf
Outputs HF Shelf, LF Shelf
Power Supply Internally regulated +/- 15V
Mains Power Internal unit
AC mains input 100 to 230V a.c.
@ 47-63Hz
Internally wired to
country voltage
Power consumption 18VA max
Mains fuse rating
100-120V a.c. use
T630mA 20mm
220-240V a.c. use
T315mA 20mm
DC Power Backup External d.c. power
supply or batteries
+/-12V to 16V d.c.
@ 300mA
Mechanical specifications - Dimensions in mm
Width Height Depth
Desktop 483 44 260
(19") (1.7") (10.2")
Weight 4kg
(9lb)
Technical Specifications
0dBu = 0.775 Volts rms, +4dBu = 1.23V rms,
0dBV = 1 Volt rms, -10dBV = 316mV rms
:
Ducking
The GR05 allows ducking and muting of
channels, and is configured either internally on
jumpers or externally via an opto-isolated input
for external trigger.
A status LED on the front panel is provided.
Expander / Remote
Additional mic & line inputs can be provided via
another ‘slave’ GR05 using the 25-pin D-type
female connector.
Lock Out System
Input controls are always active; output levels
controls may be disabled. All level controls may
be set in 3 ways: 1) Knob fitted for operator control
2) knob removed for screwdriver preset 3) hole
plugs (provided) fitted to lock out control.
PSU
Internal mains voltage PSU. DC backup input is
provided. Status indicator.