GL2200 USER GUIDE
5
KEY FEATURES OF THE GL2200
The ALLEN & HEATH GL2200 offers the user the versatility to quickly adapt to the exacting demands
of live sound engineering today. The GL2200 is developed from the very successful GL2000 console,
which included mode switching to quickly convert the console from Front-of-House to On-stage
Monitor operation. In addition, the GL2200 includes 4 su/jointfilesconvert/461238/bgroups, 6 independent aux sends, stereo
mic/line channels, pink noise generator, 1kHz oscillator and lots more. It is built on the established
tradition of innovative British design and manufacture. The GL2200 is equally suited to home and
studio recording. Features include:
FOH/stage-monitor dual functionality
4 groups, 6 auxes
Groups, L, R and Mono outputs on balanced XLR
12, 16, 24 and 32 channel frames
2 stereo line channels with mic capability
2 stereo returns with mutes, faders, EQ and Aux sends
Mutes on Groups and L-R
Channel direct outs
2-track send and return
4-band EQ with swept mids and in/out switch
Input metering on each channel
Phantom Power 48V, switchable on each channel
Inserts on all mono inputs
Inserts on Groups (auxes) and L-R outs
Comprehensive AFL/PFL monitoring
Pink noise generator for speaker setup
Oscillator for equipment line up
Talkback facility
High-performance internal power supply with universal mains input voltage
Built-in combiner to add external backup power supply
Console lamp connector
Sys-link
TM
expandability
Rugged build quality
The console is constructed using zinc plated steel panels and 1.6mm thick metal side plates.
Individual circuit board assemblies are accessible by removal of the steel base. A durable soft front
armrest is provided for comfort. A channel top write-on strip is provided for channel marking. High
quality reliable parts are used throughout. High performance op-amp and discrete circuits are used to
ensure low noise and sonic purity. The internal power supply is a low noise switch mode unit that can
be linked with an external DC power supply.
THE RANGE
12, 16, 24 and 32 channel models
GL2200-412
10 mono, 2 stereo, 4 groups, 6 aux, 2 stereo returns, L, R, Mono sum
GL2200-416
14 mono, 2 stereo, 4 groups, 6 aux, 2 stereo returns, L, R, Mono sum
GL2200-424
22 mono, 2 stereo, 4 groups, 6 aux, 2 stereo returns, L, R, Mono sum
GL2200-432
30 mono, 2 stereo, 4 groups, 6 aux, 2 stereo returns, L, R, Mono sum
OPTIONS
GL2200-SL1
Sys-link buss expander, one kit per console
RPS11-3C
3U rack mount power supply for backup
002-225
RPS11 to GL2200 DC cable assembly