Qu-16 User Guide 34 AP9031 iss.2
The Global Filter screen
A scene stores all mix parameters. A Recall Filter can
be set to protect (block) chosen parameters from
being overwritten when the scene is recalled.
The Global Filter protects parameters from being
overwritten by any of the 100 scenes.
A red dot o appears in the tab if one or more items
have been blocked.
Custom Layer – Protects the strip assignments and
settings of the Custom fader layer from being changed
when any scene is recalled.
SoftKeys – Protects the assignments of the 4 SoftKeys
from being changed when any scene is recalled.
Note – The full Scene Filter function is not available
with firmware V1.1.
The Safes screen
Scene recall affects all input channels, FX and mixes.
You can make one or more of these ‘Scene Safe’ so
that none of their parameters are overwritten by any of
the 100 scenes. For example, walk-in music and
continuity microphone channels.
A blue dot o appears in the tab if one or more
channels have been made safe.
Input Safes – Make any combination of the sources to
the mixes safe:
Mono inputs CH1-16
Stereo inputs ST1-3
FX returns FX1-3
This protects its:
Channel processing,
Channel fader and pan
Routing and sends to all the mixes
Mute Group assignments
Mix Safes – Make any combination of the mixes safe:
Mono Mix1-4
Stereo Mix5-10
FX sends FX1-2
Main LR mix
This protects its:
Master processing,
Master fader and balance
Routing and sends from the channels
Global channel send source
Mute Group assignments
A Recall Filter protects one
parameter type for all channels.
A Recall Safe protects all
parameters for one channel.